
Data Center 32-Zone High Security System - Multi-Layered Protection
Key Features
- 32 configurable security zones with 64-zone expansion capacity for future growth
- 20 high-definition cameras including 12x 4K (8MP), 4x PTZ (20x zoom), and 4x thermal imaging units
- 28 specialized detectors: 12 dual-tech (90% false alarm reduction), 8 door contacts, 8 smoke detectors
- Multi-factor access control for 8 doors with biometric + card + PIN authentication
- Grid-redundant power with 4-8 hour UPS backup and 24/7 full-service professional monitoring
Description
SOLARTODO Data Center 32-Zone High Security System
Uncompromising Protection for Mission-Critical Infrastructure
The SOLARTODO Data Center 32-Zone High Security system is an integrated, multi-layered security solution engineered to provide uncompromising protection for mission-critical data centers, government facilities, and other high-value infrastructure. This pre-configured system combines advanced intrusion detection, state-of-the-art surveillance, and stringent access control into a cohesive and resilient architecture. Designed in compliance with rigorous industry standards, including EN 50131 Grade 3 and IEC 62676, the system ensures operational continuity and data integrity by neutralizing threats before they can impact core assets. With 32 configurable zones, 20 high-definition cameras, and 28 specialized detectors, it offers a comprehensive defense-in-depth strategy against unauthorized access, theft, and environmental hazards.
Core Components and Architecture
The system's architecture is built upon a foundation of enterprise-grade components, each selected for its reliability, performance, and adherence to international security standards. The configuration includes a powerful central alarm panel, a sophisticated network of sensors and cameras, and a robust power redundancy framework.
Alarm Control Panel and Zone Management
At the heart of the system is the hybrid 64-zone alarm panel, providing centralized command and control. The included configuration utilizes 32 zones, offering significant expansion capacity for future growth. This panel supports both wired and wireless detectors, allowing for flexible deployment across complex facility layouts. It complies with EN 50131-1 Grade 3, ensuring a high level of resilience against tampering and intrusion attempts. The system includes four ergonomic LCD keypads for distributed system management, enabling security personnel to arm, disarm, and monitor specific partitions from multiple locations within the facility. Two biometric readers are integrated for high-security areas, requiring multi-factor authentication.
Detection and Sensing Layer
A sophisticated array of 28 detectors forms the primary sensing layer, designed for high accuracy and minimal false alarms. The package includes:
- 12 Dual-Technology Motion Detectors: These units combine passive infrared (PIR) and microwave sensors. An alarm is triggered only when both technologies detect an intruder, drastically reducing false alarms from environmental factors by over 90% compared to single-technology detectors. They provide volumetric protection for critical interior spaces.
- 8 Magnetic Door Contacts: Deployed at all primary and secondary entry points, these contacts immediately detect the unauthorized opening of doors, server cabinets, or maintenance panels.
- 8 Photoelectric Smoke Detectors: Conforming to NFPA 72 (National Fire Alarm and Signaling Code), these detectors provide early warning of fire hazards, a critical requirement for data center environments. They are integrated with the central panel and an FM-200 fire suppression system for automated response.
Surveillance and Visual Verification
The visual verification subsystem is built around a network of 20 high-performance cameras, managed by a 24-channel Network Video Recorder (NVR) that supports H.265+ compression for efficient storage.
- 12 4K Ultra HD Cameras: These IP cameras deliver crystal-clear 8-megapixel resolution, capturing forensic-level detail. With an infrared (IR) illumination range of up to 150 meters, they provide exceptional performance in complete darkness.
- 4 Pan-Tilt-Zoom (PTZ) Cameras: Featuring 20x optical zoom, these cameras allow operators to actively track suspicious individuals and zoom in to identify faces or license plates at a distance.
- 4 Thermal Radiometric Cameras: Capable of detecting human-sized targets at over 300 meters regardless of lighting conditions, these cameras are ideal for perimeter surveillance and detecting intruders attempting to conceal themselves. The thermal technology provides an additional layer of analytics, identifying temperature anomalies that could indicate equipment failure or fire risk.
The NVR provides 30 days of continuous 4K video retention with RAID storage for data redundancy, ensuring that critical footage is never lost due to a single drive failure. AI-powered analytics, including person/vehicle classification, line crossing, and object removal detection, automate monitoring and provide intelligent alerts to the 24/7 full-service monitoring team.
Access Control and Identity Management
Access to sensitive areas is governed by a multi-factor authentication system controlling 8 doors. The system utilizes a combination of biometric verification, PIN codes, and access cards, adhering to the principle of layered security as recommended by UL 681 (Standard for Installations and Classifications of Burglar and Holdup Alarm Systems). The two included biometric readers are deployed at the most critical entry points, such as the main data hall and network operations center, creating mantrap or airlock-style entries where identity must be verified at each stage.
Power and Redundancy
Recognizing that security systems are only effective if they are powered, the Data Center 32-Zone system features a grid-redundant power architecture. A central Uninterruptible Power Supply (UPS) provides 4-8 hours of immediate backup autonomy for the entire system in the event of a grid failure, ensuring no interruption in protection. This design allows sufficient time for a secondary power source, such as a facility-wide generator, to come online. All communication pathways feature similar redundancy, with an encrypted AES-256 Ethernet connection backed by a 4G LTE cellular module to prevent any single point of failure in communication with the central monitoring station.
Multi-Layered Security Strategy
The system implements a defense-in-depth strategy, creating concentric layers of security that an intruder must overcome.
- Perimeter Defense: The first layer is established by the thermal and PTZ cameras monitoring the facility's perimeter, detecting potential threats before they reach the building.
- Building Envelope Protection: The second layer secures the building itself, with door contacts on all entry points and dual-tech detectors covering lobbies and corridors.
- Interior Zone Control: The third layer involves segmenting the interior into 32 distinct zones. A breach in one zone, such as a utility corridor, does not compromise higher-security zones like the main data hall.
- High-Security Area Protection: The final layer is at the most critical areas, where access is restricted by multi-factor biometric authentication. This ensures that only authorized personnel can enter the most sensitive parts of the facility.
Technical Specifications
| Security Zones | 32zones |
| Maximum Zone Capacity | 64zones |
| Total Cameras | 20cameras |
| 4K IP Cameras | 12units |
| PTZ Cameras | 4units |
| Thermal Cameras | 4units |
| Total Detectors | 28detectors |
| Dual-Tech Motion Detectors | 12units |
| Door Contacts | 8units |
| Smoke Detectors | 8units |
| NVR Channels | 24channels |
| Video Storage Duration | 30days |
| Video Resolution | 4K(8MP) |
| IR Night Vision Range | 150meters |
| Thermal Detection Range | 300+meters |
| Access Control Doors | 8doors |
| Biometric Readers | 2units |
| LCD Keypads | 4units |
| Power System | Grid + UPSredundant |
| UPS Backup Duration | 4-8hours |
| Communication | Ethernet + 4G LTEencrypted |
| Monitoring Type | 24/7 Full Serviceprofessional |
| Fire Suppression | FM-200system |
| Compliance Standards | EN 50131 Grade 3, IEC 62676, UL 681, NFPA 72certified |
| Warranty | 2 years parts, 1 year labor |
Price Breakdown
| Item | Quantity | Unit Price | Subtotal |
|---|---|---|---|
| Alarm Control Panel (64-zone hybrid) | 1 pcs | $450 | $450 |
| LCD Keypad | 4 pcs | $85 | $340 |
| Dual-Tech Motion Detector | 12 pcs | $65 | $780 |
| Magnetic Door Contact | 8 pcs | $15 | $120 |
| Photoelectric Smoke Detector | 8 pcs | $40 | $320 |
| 4K IP Camera (8MP, 150m IR) | 12 pcs | $150 | $1,800 |
| PTZ Camera (20x optical zoom) | 4 pcs | $450 | $1,800 |
| Thermal Radiometric Camera | 4 pcs | $1,200 | $4,800 |
| Network Video Recorder (24-channel, H.265+) | 1 pcs | $600 | $600 |
| Biometric Access Control Reader | 2 pcs | $280 | $560 |
| Access Control Panel (8-door) | 1 pcs | $380 | $380 |
| Electromagnetic Door Lock | 8 pcs | $75 | $600 |
| Indoor/Outdoor Siren | 4 pcs | $55 | $220 |
| FM-200 Fire Suppression System | 1 pcs | $8,500 | $8,500 |
| UPS Backup Power System (4-8hr) | 1 pcs | $2,800 | $2,800 |
| Power Distribution & Redundancy Module | 1 pcs | $950 | $950 |
| Network Switches & Communication Hardware | 1 pcs | $680 | $680 |
| Cabling, Conduit & Installation Materials | 1 pcs | $3,200 | $3,200 |
| Professional Installation (32 zones) | 32 pcs | $50 | $1,600 |
| System Configuration & Testing | 1 pcs | $1,800 | $1,800 |
| 24/7 Monitoring Service (12 months) | 12 pcs | $45 | $540 |
| Training & Documentation | 1 pcs | $850 | $850 |
| Contingency & Project Management | 1 pcs | $4,500 | $4,500 |
| Total Price Range | $68,000 - $95,000 | ||
Frequently Asked Questions
What industry standards does this system comply with?
How does the system prevent false alarms?
What is the system's backup power capability?
Can the system be expanded in the future?
What does the full-service monitoring include?
Certifications & Standards
Data Sources & References
- •EN 50131 Standard (CENELEC 2017)
- •IEC 62676 Video Surveillance Standard
- •UL 681 Alarm System Standard
- •NFPA 72 Fire Alarm Code 2022
Project Cases


Interested in this solution?
Contact us for a customized quote based on your specific requirements.
Contact Us