Data Center 32-Zone High Security System - Multi-Layered Protection
Security System

Data Center 32-Zone High Security System - Multi-Layered Protection

EPC Price Range
$68,000 - $95,000

Key Features

  • 32 configurable security zones with 64-zone expansion capacity for future growth
  • 20 high-definition cameras including 12x 4K (8MP), 4x PTZ (20x zoom), and 4x thermal imaging units
  • 28 specialized detectors: 12 dual-tech (90% false alarm reduction), 8 door contacts, 8 smoke detectors
  • Multi-factor access control for 8 doors with biometric + card + PIN authentication
  • Grid-redundant power with 4-8 hour UPS backup and 24/7 full-service professional monitoring

Description

SOLARTODO Data Center 32-Zone High Security System

Uncompromising Protection for Mission-Critical Infrastructure

The SOLARTODO Data Center 32-Zone High Security system is an integrated, multi-layered security solution engineered to provide uncompromising protection for mission-critical data centers, government facilities, and other high-value infrastructure. This pre-configured system combines advanced intrusion detection, state-of-the-art surveillance, and stringent access control into a cohesive and resilient architecture. Designed in compliance with rigorous industry standards, including EN 50131 Grade 3 and IEC 62676, the system ensures operational continuity and data integrity by neutralizing threats before they can impact core assets. With 32 configurable zones, 20 high-definition cameras, and 28 specialized detectors, it offers a comprehensive defense-in-depth strategy against unauthorized access, theft, and environmental hazards.

Core Components and Architecture

The system's architecture is built upon a foundation of enterprise-grade components, each selected for its reliability, performance, and adherence to international security standards. The configuration includes a powerful central alarm panel, a sophisticated network of sensors and cameras, and a robust power redundancy framework.

Alarm Control Panel and Zone Management

At the heart of the system is the hybrid 64-zone alarm panel, providing centralized command and control. The included configuration utilizes 32 zones, offering significant expansion capacity for future growth. This panel supports both wired and wireless detectors, allowing for flexible deployment across complex facility layouts. It complies with EN 50131-1 Grade 3, ensuring a high level of resilience against tampering and intrusion attempts. The system includes four ergonomic LCD keypads for distributed system management, enabling security personnel to arm, disarm, and monitor specific partitions from multiple locations within the facility. Two biometric readers are integrated for high-security areas, requiring multi-factor authentication.

Detection and Sensing Layer

A sophisticated array of 28 detectors forms the primary sensing layer, designed for high accuracy and minimal false alarms. The package includes:

  • 12 Dual-Technology Motion Detectors: These units combine passive infrared (PIR) and microwave sensors. An alarm is triggered only when both technologies detect an intruder, drastically reducing false alarms from environmental factors by over 90% compared to single-technology detectors. They provide volumetric protection for critical interior spaces.
  • 8 Magnetic Door Contacts: Deployed at all primary and secondary entry points, these contacts immediately detect the unauthorized opening of doors, server cabinets, or maintenance panels.
  • 8 Photoelectric Smoke Detectors: Conforming to NFPA 72 (National Fire Alarm and Signaling Code), these detectors provide early warning of fire hazards, a critical requirement for data center environments. They are integrated with the central panel and an FM-200 fire suppression system for automated response.

Surveillance and Visual Verification

The visual verification subsystem is built around a network of 20 high-performance cameras, managed by a 24-channel Network Video Recorder (NVR) that supports H.265+ compression for efficient storage.

  • 12 4K Ultra HD Cameras: These IP cameras deliver crystal-clear 8-megapixel resolution, capturing forensic-level detail. With an infrared (IR) illumination range of up to 150 meters, they provide exceptional performance in complete darkness.
  • 4 Pan-Tilt-Zoom (PTZ) Cameras: Featuring 20x optical zoom, these cameras allow operators to actively track suspicious individuals and zoom in to identify faces or license plates at a distance.
  • 4 Thermal Radiometric Cameras: Capable of detecting human-sized targets at over 300 meters regardless of lighting conditions, these cameras are ideal for perimeter surveillance and detecting intruders attempting to conceal themselves. The thermal technology provides an additional layer of analytics, identifying temperature anomalies that could indicate equipment failure or fire risk.

The NVR provides 30 days of continuous 4K video retention with RAID storage for data redundancy, ensuring that critical footage is never lost due to a single drive failure. AI-powered analytics, including person/vehicle classification, line crossing, and object removal detection, automate monitoring and provide intelligent alerts to the 24/7 full-service monitoring team.

Access Control and Identity Management

Access to sensitive areas is governed by a multi-factor authentication system controlling 8 doors. The system utilizes a combination of biometric verification, PIN codes, and access cards, adhering to the principle of layered security as recommended by UL 681 (Standard for Installations and Classifications of Burglar and Holdup Alarm Systems). The two included biometric readers are deployed at the most critical entry points, such as the main data hall and network operations center, creating mantrap or airlock-style entries where identity must be verified at each stage.

Power and Redundancy

Recognizing that security systems are only effective if they are powered, the Data Center 32-Zone system features a grid-redundant power architecture. A central Uninterruptible Power Supply (UPS) provides 4-8 hours of immediate backup autonomy for the entire system in the event of a grid failure, ensuring no interruption in protection. This design allows sufficient time for a secondary power source, such as a facility-wide generator, to come online. All communication pathways feature similar redundancy, with an encrypted AES-256 Ethernet connection backed by a 4G LTE cellular module to prevent any single point of failure in communication with the central monitoring station.

Multi-Layered Security Strategy

The system implements a defense-in-depth strategy, creating concentric layers of security that an intruder must overcome.

  1. Perimeter Defense: The first layer is established by the thermal and PTZ cameras monitoring the facility's perimeter, detecting potential threats before they reach the building.
  2. Building Envelope Protection: The second layer secures the building itself, with door contacts on all entry points and dual-tech detectors covering lobbies and corridors.
  3. Interior Zone Control: The third layer involves segmenting the interior into 32 distinct zones. A breach in one zone, such as a utility corridor, does not compromise higher-security zones like the main data hall.
  4. High-Security Area Protection: The final layer is at the most critical areas, where access is restricted by multi-factor biometric authentication. This ensures that only authorized personnel can enter the most sensitive parts of the facility.

Technical Specifications

Security Zones32zones
Maximum Zone Capacity64zones
Total Cameras20cameras
4K IP Cameras12units
PTZ Cameras4units
Thermal Cameras4units
Total Detectors28detectors
Dual-Tech Motion Detectors12units
Door Contacts8units
Smoke Detectors8units
NVR Channels24channels
Video Storage Duration30days
Video Resolution4K(8MP)
IR Night Vision Range150meters
Thermal Detection Range300+meters
Access Control Doors8doors
Biometric Readers2units
LCD Keypads4units
Power SystemGrid + UPSredundant
UPS Backup Duration4-8hours
CommunicationEthernet + 4G LTEencrypted
Monitoring Type24/7 Full Serviceprofessional
Fire SuppressionFM-200system
Compliance StandardsEN 50131 Grade 3, IEC 62676, UL 681, NFPA 72certified
Warranty2 years parts, 1 year labor

Price Breakdown

ItemQuantityUnit PriceSubtotal
Alarm Control Panel (64-zone hybrid)1 pcs$450$450
LCD Keypad4 pcs$85$340
Dual-Tech Motion Detector12 pcs$65$780
Magnetic Door Contact8 pcs$15$120
Photoelectric Smoke Detector8 pcs$40$320
4K IP Camera (8MP, 150m IR)12 pcs$150$1,800
PTZ Camera (20x optical zoom)4 pcs$450$1,800
Thermal Radiometric Camera4 pcs$1,200$4,800
Network Video Recorder (24-channel, H.265+)1 pcs$600$600
Biometric Access Control Reader2 pcs$280$560
Access Control Panel (8-door)1 pcs$380$380
Electromagnetic Door Lock8 pcs$75$600
Indoor/Outdoor Siren4 pcs$55$220
FM-200 Fire Suppression System1 pcs$8,500$8,500
UPS Backup Power System (4-8hr)1 pcs$2,800$2,800
Power Distribution & Redundancy Module1 pcs$950$950
Network Switches & Communication Hardware1 pcs$680$680
Cabling, Conduit & Installation Materials1 pcs$3,200$3,200
Professional Installation (32 zones)32 pcs$50$1,600
System Configuration & Testing1 pcs$1,800$1,800
24/7 Monitoring Service (12 months)12 pcs$45$540
Training & Documentation1 pcs$850$850
Contingency & Project Management1 pcs$4,500$4,500
Total Price Range$68,000 - $95,000

Frequently Asked Questions

What industry standards does this system comply with?
The system is designed to meet or exceed several key international standards, ensuring its suitability for high-security applications. These include EN 50131-1 Grade 3 for intrusion and hold-up systems, IEC 62676 for video surveillance systems, UL 681 for alarm installations, and NFPA 72 for fire alarm and signaling. This multi-standard compliance guarantees a robust, reliable, and interoperable security solution for critical infrastructure protection.
How does the system prevent false alarms?
False alarms are minimized through a combination of advanced hardware and intelligent software. The 12 dual-technology detectors require both PIR and microwave sensors to trigger, reducing environmentally-caused false alarms by over 90%. Furthermore, the camera system employs AI-powered video analytics to differentiate between humans, vehicles, and other objects, ensuring that alerts sent to the monitoring station are relevant and actionable, which is a key requirement for effective security operations.
What is the system's backup power capability?
The system features a grid-redundant power design. In the event of a primary power outage, an integrated Uninterruptible Power Supply (UPS) instantly takes over, providing 4 to 8 hours of continuous operation for all security components. This autonomy allows ample time for the facility's backup generator to activate, ensuring the security posture is maintained without interruption during extended grid failures. The design ensures 100% uptime for the entire security infrastructure.
Can the system be expanded in the future?
Yes, the system is highly scalable. The core alarm panel supports up to 64 zones, while the current configuration uses 32. This provides a 100% expansion capacity for additional detectors. The 24-channel NVR can also be expanded or supplemented to accommodate more cameras as your facility grows. This modular design allows the security system to evolve alongside your operational needs, protecting your initial investment while providing a clear path for future upgrades.
What does the full-service monitoring include?
Full-service monitoring provides 24/7/365 professional oversight from a secure, remote command center. Trained operators receive and verify all system alerts, including intrusion, fire, and technical faults. They can access live and recorded video to assess situations, dispatch law enforcement or emergency services, and manage access remotely. This service transforms the system from a passive deterrent into an active, real-time security operation, ensuring immediate and appropriate response to any incident.

Certifications & Standards

EN 50131-1 Grade 3
IEC 62676
IEC 62676
UL 681
NFPA 72
CE
CE
FCC Part 15
FCC Part 15

Data Sources & References

  • EN 50131 Standard (CENELEC 2017)
  • IEC 62676 Video Surveillance Standard
  • UL 681 Alarm System Standard
  • NFPA 72 Fire Alarm Code 2022

Project Cases

Data Center 32-Zone High Security System - Multi-Layered Protection - 1
Data Center 32-Zone High Security System - Multi-Layered Protection - 2

Interested in this solution?

Contact us for a customized quote based on your specific requirements.

Contact Us